Fiber Driver
EM316E1/EM316T1
P/N: 1218003-001, REV_O PAGE 7
Connectivity
Connectors Used
Fiber: ST, or SC-APC (for single fiber)
UTP: RJ48-MDI
Coax: BNC (2 connectors: 1 for TX, 1 for RX)
Cable Requirement
Fiber: ST-ST fiber cable, or SC-APC fiber cable (for single fiber)
UTP: Category 5
Coax: RG58/U
Port Description
Input: E1 (BNC) or T1 (UTP-RJ48)
Output: Fiber Modem, Multi-Mode: 1310nm, 0-2km
Single Mode: 1310nm, 0-25km
Single Mode: 1310nm, 25-50km
Single Mode: 1550nm, 50-100km
Connector Pin-out
Female RJ-48 (MDI)
1 RRING 5 TTIP
2 RTIP 6 Unused
3 Unused 7 Unused
4 TRING 8 Unused
1
2
4
5
1
2
4
5
Crossed Cable Pin-Out
Figure 2
18
RJ48 Connector Pin-Out
Figure 1