Configuring Power Control Units
Naming an Outlet 10-5
Naming an Outlet
You can assign a descriptive name of up to 15 alphanumeric
characters to an outlet.
X To specify a descriptive name for an outlet
Use the outlet name command in Asynchronous Command
Mode. In the following example, the descriptive name
Build5NTserver is assigned to Outlet 2 on the Power Control
unit that is managed from POWER port 5:
Example Async5:0 >>outlet 2 name Build5NTserver
L The POWER port number is not specified in the
outlet name command (such as 5:2) because the
POWER port is implied to be the current port in the
Asynchronous Command Mode. In the preceding
example, the implied POWER port is port 5. The CLI is
in the Asynchronous Command Mode for port 5.
Naming an Outlet Group
You can assign a descriptive name of up to 15 alphanumeric
characters to an outlet group.
X To specify a descriptive name for an outlet group
Use the outlet group name command in Configuration
Command Mode. In the following example, the descriptive
name TestEquipment is assigned to outlet group 14:
Example Config:0 >>outlet group 14 name TestEquipment