MRV Communications LX-4000 Series Información técnica Pagina 489

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 692
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 488
Alarm Input/Control Output Points
Configuring Alarm Inputs via Trigger Action Rules 19-7
L See the LX-Series Configuration Guide for more
information.
6. Create the Notification Profile for the user:
Example InReach:0 >> config
Config:0 >> notification
Notification:0 >> profile user ricksnmp service
ricksnmp
Noti_User_Info:0 >> facility user
Noti_User_Info:0 >> priority notice
Noti_User_Info:0 >> exit
Notification:0 >> end
InReach:0 >>
7. Enable the Rules:
L Each rule can be enabled when it is created with the
single command enable. In this step we will enable
all rules configured in one step.
Example InReach:0 >> config
Config:0 >> trigger rule all enable
Config:0 >> exit
InReach:0 >>
8. Select DTR or RTS as the controlling voltage for the Alarm
Input signal. In this example DTR is used to provide the
controlling voltage and the port # is port 10.
9. Set the selected signal up as a Control Output with a
default High state:
Example InReach:0 >> config port async 10 access control
InReach:0 >> control port async 10 dtr high
L The control port command can be used to test the
functionality of the configuration.
Vista de pagina 488
1 2 ... 484 485 486 487 488 489 490 491 492 493 494 ... 691 692

Comentarios a estos manuales

Sin comentarios