15-46 Naming Alarm Inputs
LX Series Configuration Guide
X To reset the alarm input name to default for a
specific alarm or multiple alarms
Use the following command syntax:
Syntax ldam alarm <alarm_name> default name
ldam alarm port <port_number> point <point_number>
default name
where
Examples
X To reset the alarm input point to default for a
specific alarm or multiple alarms
Use the following command syntax:
Syntax ldam alarm <alarm_name> default point
ldam alarm port <
port_number> point <point_number>
default
where
Examples
alarm_name Specifies an Alarm Input Name. The value of alarm_
name can be a descriptive name or a default name.
port_number Specifies the LDAM port number.
point_number Specifies the point you want to reset to the default
name. Options are 1 and 2.
Config:0 >>ldam alarm port 2 point 1 default name
Config:0 >>ldam alarm port 2 point 2 default name
Config:0 >>ldam alarm fan_window default name
alarm_name Specifies an Alarm Input Name. The value of alarm_
name can be a descriptive name or a default name.
port_number Specifies the LDAM port number.
point_number Specifies the point you want to reset to the default
name. Options are 1 and 2.
Config:0 >>ldam alarm port 2 point 1 default poin
Config:0 >>ldam alarm port 2 point 2 default poin
Config:0 >>ldam alarm fan_window default point
Comentarios a estos manuales