L-10 Advanced LXPORTD Application
LX Series Configuration Guide
Config:0>>port async 1-32 no authentication
outbound
Config:0>>port async 1-32 no autohangup
Config:0>>port async 1-32 no telnet negotiations
Config:0>>port async 1-32 speed 57600
Config:0>>port async 1-32 flowcontrol cts
Config:0>>port async 1-32 parity none
Config:0>>port async 1-32 character 8
Config:0>>interface 1 broadcast group 1 master port
tcp 1024 - this is the TCP port Lxportd will connect to at
start-up time.
Config:0>>interface 1 broadcast group 1 mode char -
pass characters along as the LX receives them.
Config:0>>interface 1 broadcast group 1 virtual
authentication radius enable - The security method will
be RADIUS. It is assumed that RADIUS has already been set
up on the LX and is functioning properly.
Config:0>>interface 1 broadcast group 1 slave port
async 1-32 - all 32 serial ports will be slaves. Ports 1-31
will have TV monitors attached. Port 32 will have a crossover
cable attached that will go to port 1 of the next LX in line (see
the diagram above and the LX32 port slave unit #1
configuration below).
Config:0>>interface 1 broadcast group 1 enabled -
this enables the broadcast group.
LX 32 port slave units #1, #2 and #3 configuration consist of
one broadcast master async port (port 1), with serial ports 2-32
acting as broadcast slaves. All three LX slave units #1, #2, and
#3 should be configured as follows (exceptions are noted
below).
Enter the following commands:
Config:0>>interface 1broadcast group 1 master port
async 1