15-42 Naming Alarm Inputs
LX Series Configuration Guide
Naming Alarm Inputs
The default name for an alarm input is canonically derived from
the port number and point number. You can configure by the
default name (if known).
L You can use each point name after on the LX. You
can’t use the same name on multiple ports or points.
X To configure a descriptive name for any alarm input
Use the following
Privileged command syntax:
Syntax ldam alarm <alarm_name_1> name <alarm_name_2>
ldam alarm port <
port_number> point <point_number> name
<
new_name>
where
Examples
alarm_name_1
Name of the alarm input to rename
alarm_name_2
New alarm name to assign to the alarm input. The
name must start with a letter, and the remainder of
the name can contain only letters and/or numbers
and/or underscores
port_number
Specifies the LDAM port number
point_number
A specific point for which to configure a name
new_name
New name for the point
All names
across the
Master LX
Unit must
be unique.
Config:0 >>ldam alarm 5_2 name BankVaultDoor
Config:0 >>ldam alarm port 5 point 2 name BankVaultDoor
InReach:0 >>config ldam alarm port 5 point 2 name BankVaultDoo