MRV Communications LX-4000 Series Información técnica Pagina 438

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 692
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 437
15-50 Naming Control Outputs
LX Series Configuration Guide
X To configure a control output description string for a
specific control
Use the following command syntax:
Syntax ldam control <control_name> description <string>
ldam control port <
port_number> point <point_number>
description <
string>
where
Examples
control_name Specifies a Control Output Name. The default name
for an alarm input or control output is canonically
derived from the port number, slot number and
point number. For example, the default name for
the 1st control output being managed by LDAM port
5 is 5_1.
port_number Specifies the LDAM port number.
point_number The point whose description you want to set. The
only option is 1.
string The description of the control output (a maximum of
63 characters long).
Config:0 >>ldam control Floor2Lab description lab door
1
Config:0 >>ldam control 3_1 description lab door 2
Config:0 >>ldam control port 2 point 1 description lab1
Vista de pagina 437
1 2 ... 433 434 435 436 437 438 439 440 441 442 443 ... 691 692

Comentarios a estos manuales

Sin comentarios