3-4 Configuring Ports for Remote Console Management
LX Series Configuration Guide
Configuring Ports for Remote Console
Management
This section describes how to configure LX asynchronous ports
for remote console management.
Configuring Asynchronous Ports for Direct
Serial Connections
The default settings for LX asynchronous ports will support
direct serial connections to most Network Elements. However,
when conditions warrant, you can explicitly set an asynchronous
port to non-default values.
L Autobaud must be disabled on ports that are used for
remote console management. To disable autobaud
on a port, execute the no autobaud command in the
Asynchronous command mode.
Explicitly Setting LX Asynchronous Port
Characteristics
You should explicitly set the characteristics of an
LX asynchronous port to match those of a directly connected
Network Element.
X To explicitly set the characteristics of an
LX asynchronous port
1. Access the Asynchronous Command Mode for the
asynchronous port to configure.
2. Use the access remote command in to set the access for
the asynchronous port to remote:
Example Async 6-6:0 >>access remote
See “Command
Mode
Descriptions” on
page 1-5 for
information abou
accessing
Asynchronous
Command Mode.